Abstract

BackgroundMagnetic fluid hyperthermia (MFH) represents a promising therapeutic strategy in cancer utilizing the heating capabilities of magnetic nanoparticles when exposed to an alternating magnetic field (AMF). Because the efficacy and safety of MFH treatments depends on numerous intrinsic and extrinsic factors, therefore, the proper MFH setups should focus on thermal energy dosed into the cancer cells.MethodsIn this study, we performed MFH experiments using human lung cancer A549 cells (in vitro) and NUDE Balb/c mice bearing human lung (A549) cancer (in vivo). In these two experimental models, the heat was induced by magnesium-doped iron(III) oxide nanoparticles coated with mPEG-silane (Mg0.1-γ-Fe2O3(mPEG-silane)0.5) when exposed to an AMF.ResultsWe observed that the lung cancer cells treated with Mg0.1-γ-Fe2O3(mPEG-silane)0.5 (0.25 mg·mL−1) and magnetized for 30 min at 14.4 kA·m−1 yielded a satisfactory outcome in reducing the cell viability up to ca. 21% (in vitro). The activation energy calculated for this field strength was estimated for 349 kJ·mol−1. Both volumetric measurements and tumor mass assessments confirmed by magnetic resonance imaging (MRI) showed a superior thermal effect in mice bearing human lung cancer injected intratumorally with Mg0.1-γ-Fe2O3(mPEG-silane)0.5 nanoparticles (3 mg·mL−1) and subjected to an AMF (18.3 kA·m−1) for 30 min four times at weekly intervals. Research demonstrated that mice undergoing MFH exhibited a marked suppression of tumor growth (V = 169 ± 94 mm3; p < 0.05) in comparison to the control group of untreated mice. The CEM43 (cumulative number of equivalent minutes at 43 °C) value for these treatments were estimated for ca. 9.6 min with the specific absorption rate (SAR) level ranging from 100 to 150 W·g−1.ConclusionsThe as-obtained results, both cytotoxic and those related to energy calculations and SAR, may contribute to the advancement of thermal therapies, concurrently indicating that the proposed magnetic fluid hyperthermia holds a great potential for further testing in the context of medical applications.Graphical

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.