Abstract
The new TEA (transversely excited atmospheric pressure) CO 2 laser can produce ionization of air. No information is as yet available of the effect of this new high-power output laser on man. Repeated impacts of 30 mJ pulses with 100 kW, which produced ionization of air, caused non-specific superficial coagulation necrosis which healed promptly.