Abstract
Experimental results and a theoretical analysis are presented on structured packing liquid holdup under cryogenic conditions. The experimental tests were performed on a novel laboratory unit incorporating a gas lift pump to recirculate the cryogenic liquid in a flow visualization dewar. Holdup is measured by sensing the difference in level in the dewar when the liquid flow is shut off after a constant operation at a given liquid loading. A dimensional analysis is performed to identify the important system properties that affect the liquid holdup. The preliminary experimental data are compared against a correlation developed from the dimensional analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.