Abstract

The article considers the effect of ultrasonic exposure after the ion implantation of titanium alloys VT1-0 and VT6 silver on the thickness of the ion-leged layer, the distribution of silver by the thickness of this layer and the scalar density of dislocations in the subsurface layer. It has been established that for the alloy VT6 at the same parameters of the implantation regime there is a deeper penetration of silver ions compared to the alloy VT1-0. Directly under the ion-leged layer is formed a layer with an increased rocky density of dislocations. The ultrasonic treatment of the implanted layer on the alloys studied contributed to the deeper penetration of silver ions and the alignment of its concentration by the thickness of the surface layer of titanium alloys.