Abstract
Taking a 2 MW horizontal axis wind turbine in a wind farm in Northwest China as the research object, the structural response analysis of wind turbine considering fluid structure coupling effect under different inflow was carried out by using ANSYS Workbench software. The results show that when the incoming wind speed is cut-in wind speed, the displacement and stress change slightly; when the incoming wind speed is between the cut-in and cut-out wind speed, the structural response law of the wind turbine is the same. The maximum of displacement and stress increase with the increase of wind speed, and the maximum displacement of the blade is located in the tip, and the maximum stress of the blade is concentrated in the middle of the blade; The maximum displacement of the tower is located at the top, and the maximum stress of the tower is concentrated at the bottom. The results have important reference value for the design and safe operation of wind turbine.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have