Abstract
A precast concrete sandwich panel (PCSP) offers a good potential in the application of façade wall due to the improved energy efficiency. In this study, the structural performance of PCSP with pin-type glass fiber reinforced polymer (GFRP) connectors was investigated, and an optimization characterized by ribbed structural wythe was proposed and studied. Firstly, the pull-out and shear capacity of the pin-type connector were evaluated through direct tensile test and direct shear test, respectively. Thereafter, seven PCSP specimens were fabricated and tested under four points flexural load. The investigating parameters included the structural wythe thickness, loading direction, insulation bond, and section type of the structural wythe. The load-deflection relationship, crack pattern, failure mode, load-strain relationship, and degree of composite action of the PCSP were studied and compared. It was concluded that: (1) the tested PCSPs presented ductile failures; (2) the structural wythe thickness, loading direction and insulation bond would influence the cracking, yielding, and peak loads of the tested PCSP; (3) the PCSP with pin-type GFRP connectors could be designed as non-composite type owing to the low composite action; and (4) the proposed ribbed structural wythe could achieve a lightweight PCSP while considerable flexural stiffness and capacity could be retained.