Abstract

Structural health monitoring of rotary aerospace structures is investigated in this research. A monitoring system is proposed based on the electromechanical impedance spectrum of piezoelectric transducers and a portable transceiver. To investigate the applicability and preliminary results of this method, a turbomachine prototype (laboratory device) is developed, and integrated composite piezoelectric films are deposited on the blades. Next, a self-diagnostic characterization is initially implemented to the piezo-films. Transceiver functionality and accuracy is verified using an Ivium impedance analyzer. The verified measuring path was used in structural health monitoring of pristine and damaged blades at rotational speed of 0 and 1000 r/min. The effects of damage formation and rotational speed on the impedance signature are discussed based on the variations in mechanical impedance using a two-dimensional model. Once damage occurs in a blade at each speed, it results in a frequency shift of the impedance signature at antiresonance peaks compared to the corresponding baseline. The results show a clear frequency shift of existing peaks and the appearance of new peaks as damage grows to a secure minimal detectable size. This achievement confirms the applicability of this method for incipient damage detection on rotary structures prior to any failure.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call