Aiming at the limitations of magnetorheological fluid (MRF) settlement monitoring in transparent non-metallic containers, a method of MRF concentration measurement based on a wire wound inductor is proposed in this paper, and with the sensing method, in-situ monitoring of MRF sedimentation inside the damper is fulfilled. The varying local concentration of MRF will lead to the inductance change of the wire wound inductor, which is immersed in the MRF at a specific position, with the settling process. When harmonically excited with a signal generator, the relationship between the output amplitude across the inductor and the MRF concentration can be established. To reveal the settling speed dependence, the monitoring of the MRF settling is carried out with different concentrations and viscosities. It is testified that the proposed method can measure the concentration of MRF effectively, and is qualified with the in-situ monitoring of the MRF settling in a real damper.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.