Abstract

CrNxcoatings were deposited on Si (100) and WC-Co substrates by a home-made medium-frequency magnetron sputtering system with and without thermal filament ion source assistance. The structure and composition of the coatings were characterized by X-ray diffraction, atomic force microscopy, scanning electron microscopy, and transmission electron microscopy. The mechanical and tribological properties were assessed by microhardness and pin-on-disc testing. The ion source-assisted system showed a deposition rate of 3.88 μm/h, much higher than the value 2.2 μm/h without ion source assistance. The CrNxcoatings prepared with ion source assistance exhibited an increase in microhardness (up to 16.3 GPa) and adecrease in friction coefficient (down to 0.48) at the optimized cathode source-to-substrate distance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.