Abstract
This study determined the effect of epoxy-coated transverse reinforcement on the strength of epoxy-coated bar splices. Existing recommendations for design of splices and anchorage of epoxy-coated reinforcement were reviewed and modifications are suggested. Test results show that the presence of transverse reinforcement in the splice region increased deformation capacity of the beams and improved anchorage strength of epoxy-coated bar splices relative to uncoated bar splices. The improvement was independent of the number of splices, bar size, or bar spacing. Using results of this study and results of other tests on epoxy-coated bar splices in the literature, a comprehensive review of the effect of epoxy coating on structural aspect of epoxy-coated bar splices was performed. Design equations are recommended, and modifications to the ACI Building Code (ACI 318-89) development and splice length provisions are suggested.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have