Abstract

The first wall of ITER is expected to be hot isostatic pressing (HIP) bonded structure of copper-alloy/SS316. Firstly, fracture toughness and crack propagation tests were performed on DS-Cu and DS-Cu/SS316 HIP joints at ambient temperature and 573 K T. Yamada, M. Uno, M. Saito, Fall Meeting of the Atomic Energy Society of Japan, vol. I, 1998, p. 187 (in Japanese). J IC values of DS-Cu and DS-Cu/SS316 decreased significantly at 573 K. In crack propagation test, DS-Cu lost its ductility at 573 K. Secondly, we performed fracture toughness tests on CuCrZr and CuCrZr/CuCrZr, CuCrZr/SS316 HIP joints at ambient and 573 K. CuCrZr base metal had higher J IC values than DS-Cu. Concerning CuCrZr/CuCrZr and CuCrZr/SS316 HIP joint, its J IC value decreased to less than that of CuCrZr base metal.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.