Porosity and inclusion of foreign material is known to reduce the strength of materials, and this paper addresses the particular problem of strength knock-down assessment due to porosity in composite materials. Porosity is often measured in terms of percentage of voids per unit volume of a component, because this can be related directly to ultra-sound absorption. Nevertheless, this is a poor indicator of actual strength knock-down, as it provides little information about void size, shape, orientation and whether they are evenly distributed or are clustered. Characterisation of void clustering enables a link between a cluster characteristic and the strength knock-down. Laboratory based testing achieves controlled porosity in specimens by introducing pin-holes into the RTM in-flow pipework, which entrains voids into the body of the preform within mould tooling. Specimens are manufactured to create resin regions bounded by a fibre reinforced picture frame, to allow for easy load application. Strength knock-downs from test are related to the theoretical expectations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.