Abstract

Statement of problemHow the loading rate might affect the mechanical properties of interim materials and interim fixed dental prostheses is unclear. PurposeThe purpose of this in vitro study was to compare the material stiffness, material strength, and structural strength of interim 3-unit fixed dental prostheses fabricated from 3 interim materials when stressed at different loading rates. Material and methodsBar-shaped specimens and anatomically correct interim 3-unit fixed dental prostheses with a modified-ridge lap pontic were fabricated from polyethyl methacrylate resin (Trim) and 2 bis-acrylic composite resins (TempSmart; Integrity) (n=10). Flexural modulus and strength of the bar specimens, representing material stiffness and strength, were determined with a 4-point bend test in a universal testing machine. The structural strength of the prosthesis was assessed from the failure load from a vertical force applied on the occlusal surface of the pontic. Three loading rates, 0.5, 5, or 10 mm/min, were evaluated. Results were statistically analyzed with 2-way analysis of variance and multiple comparisons (α=.05). ResultsLoading rate and material significantly affected flexural modulus, flexural strength, and structural strength (P<.05). Increasing loading rate significantly increased the flexural modulus of all materials (P<.05), but the effect of loading rate on the flexural strength of bis-acrylic composite resins was mostly insignificant. Polyethyl methacrylate specimens did not fracture when loaded at 0.5 or 5 mm/min, and the interim fixed dental prostheses made from polyethyl methacrylate did not fracture at the 0.5 mm/min loading rate. Dual-polymerizing bis-acrylic composite resin had significantly higher flexural modulus and strengths than autopolymerizing bis-acrylic composite resin. ConclusionsPolyethyl methacrylate resin had the lowest stiffness among the interim materials tested and did not fracture but excessively deformed at the low loading rate. Dual-polymerizing bis-acrylic composite resin consistently had higher stiffness and material strength and provided higher structural strength than the autopolymerizing bis-acrylic composite resin. Loading rate significantly affected the mechanical properties of polyethyl methacrylate resin (P<.05), but the effect was indistinct for the bis-acrylic materials.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call