Abstract
In accordance with present-day efforts to reduce power losses in electrical machines, an analytical approach to estimate the influence of contact resistances between the skewed rotor cage and its laminated iron core on the amount of stray losses of induction motors is made in this paper. Equations for calculation of resistances of the rotor iron core, with which the stray losses due to inter-bar currents are taken into account, are presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Electrical Engineering (Archiv fur Elektrotechnik)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.