Abstract

Integrating artificial intelligence (AI) into mammography screening can support radiologists and improve programme metrics, yet the potential of different strategies for integrating the technology remains understudied. We compared programme-level performance metrics of seven AI integration strategies. We performed a retrospective comparative evaluation of seven strategies for integrating AI into mammography screening using datasets generated from screening programmes in Germany (n=1 657 068), the UK (n=223 603) and Sweden (n=22 779). The commercially available AI model used was Vara version 2.10, trained from scratch on German data. We simulated the performance of each strategy in terms of cancer detection rate (CDR), recall rate, and workload reduction, and compared the metrics with those of the screening programmes. We also assessed the distribution of the stages and grades of the cancers detected by each strategy and the AI model's ability to correctly localise those cancers. Compared with the German screening programme (CDR 6·32 per 1000 examinations, recall rate 4·11 per 100 examinations), replacement of both readers (standalone AI strategy) achieved a non-inferior CDR of 6·37 (95% CI 6·10-6·64) at a recall rate of 3·80 (95% CI 3·67-3·93), whereas single reader replacement achieved a CDR of 6·49 (6·31-6·67), a recall rate of 4·01 (3·92-4·10), and a 49% workload reduction. Programme-level decision referral achieved a CDR of 6·85 (6·61-7·11), a recall rate of 3·55 (3·43-3·68), and an 84% workload reduction. Compared with the UK programme CDR of 8·19, the reader-level, programme-level, and deferral to single reader strategies achieved CDRs of 8·24 (7·82-8·71), 8·59 (8·12-9·06), and 8·28 (7·86-8·71), without increasing recall and while reducing workload by 37%, 81%, and 95%, respectively. On the Swedish dataset, programme-level decision referral increased the CDR by 17·7% without increasing recall and while reducing reading workload by 92%. The decision referral strategies offered the largest improvements in cancer detection rates and reduction in recall rates, and all strategies except normal triaging showed potential to improve screening metrics. Vara.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.