Abstract

Attenuation and scatter correction is crucial for quantitative positron emission tomography (PET) imaging. Direct attenuation correction (AC) in the image domain using deep learning approaches has been recently proposed for combined PET/MR and standalone PET modalities lacking transmission scanning devices or anatomical imaging. In this study, different input settings were considered in the model training to investigate deep learning-based AC in the image space. Three different deep learning methods were developed for direct AC in the image space: (i) use of non-attenuation-corrected PET images as input (NonAC-PET), (ii) use of attenuation-corrected PET images with a simple two-class AC map (composed of soft-tissue and background air) obtained from NonAC-PET images (PET segmentation-based AC [SegAC-PET]), and (iii) use of both NonAC-PET and SegAC-PET images in a Double-Channel fashion to predict ground truth attenuation corrected PET images with Computed Tomography images (CTAC-PET). Since a simple two-class AC map (generated from NonAC-PET images) can easily be generated, this work assessed the added value of incorporating SegAC-PET images into direct AC in the image space. A 4-fold cross-validation scheme was adopted to train and evaluate the different models based using 80 brain 18 F-Fluorodeoxyglucose PET/CT images. The voxel-wise and region-wise accuracy of the models were examined via measuring the standardized uptake value (SUV) quantification bias in different regions of the brain. The overall root mean square error (RMSE) for the Double-Channel setting was 0.157±0.08 SUV in the whole brain region, while RMSEs of 0.214±0.07 and 0.189±0.14 SUV were observed in NonAC-PET and SegAC-PET models, respectively. A mean SUV bias of 0.01±0.26% was achieved by the Double-Channel model regarding the activity concentration in cerebellum region, as opposed to 0.08±0.28% and 0.05±0.28% SUV biases for the network that uniquely used NonAC-PET or SegAC-PET as input, respectively. SegAC-PET images with an SUV bias of -1.15±0.54%, served as a benchmark for clinically accepted errors. In general, the Double-Channel network, relying on both SegAC-PET and NonAC-PET images, outperformed the other AC models. Since the generation of two-class AC maps from non-AC PET images is straightforward, the current study investigated the potential added value of incorporating SegAC-PET images into a deep learning-based direct AC approach. Altogether, compared with models that use only NonAC-PET and SegAC-PET images, the Double-Channel deep learning network exhibited superior attenuation correction accuracy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.