Abstract

The energy loss distributions of heavy ions (Z ≤ 8) with high energies (2 MeV/u–50 MeV/u) in thick silicon detectors with uniform thickness have been measured in a wide range of fractional energy loss, Δ E / E 0 , where Δ E is the energy loss and E 0 is the initial energy of incident ions. The measured distributions of energetic He, Li, Be, B and C ions are in good agreement with those predicted from Livingston-Bethe's theory when Δ E / E 0 < 0.2. However, the distributions for large fractional energy losses Δ E / E 0 > 0.2, which are much wider than those expected from the theory, are approximately expressed by Stoquert's method considering the effect of velocity decrease into Livingston-Bethe's theory. In the previous experiment of the energy loss of heavy ions from K to Fe in thick Si detectors, Hasebe et al. obtained consistent results for heavier elements. By conbining the results in the previous and this works, it is concluded that the straggling in energy loss of heavy ions from proton to Fe with energies from about 5 MeV/u to a few hundred MeV/u in thick Si-absorber is explained by Stoquert's method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.