Abstract

In our previous work, we developed a compact 6-DOF haptic interface as a master device which achieved an effective manual teleoperation. The haptic interface contains a modified Delta parallel-link positioning mechanism. Parallel mechanisms are usually characterized by a high stiffness, which, however, is reduced by elastic deformations of both parts and bearings. Therefore, to design such a parallel mechanism, we should analyze its structural stiffness, including elastic deformations of both parts and bearings. Then we propose a simple method to analyze structural stiffness in a parallel mechanism using bearings. Our method is based on standard concepts such as static elastic deformations. However, the important aspect of our method is the manner in which we combine these concepts and how we obtain the value of the elasticity coefficient of a rotation axis in a bearing. Finally, we design a modified Delta mechanism, with a well-balanced stiffness, based on our method of stiffness analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.