Abstract

Ten patients (mean age 36.6 ± 8 years; 5 male) with idiopathic inferior vena cava obstruction underwent balloon angioplasty, followed by placement of a self-expanding stent. Six had total occlusion, 5 had restenosis (including 2 with total occlusion), and I had a suboptimal result after initial dilatation. The mean diameter of the inferior vena cava increased from 1.5 ± 2.1 mm to 14.4 ± 2.7 mm, and the pressure gradient between the vena cava and the right atrium decreased from 15.2 ± 5.0 mm Hg to 1.1 ± 1.5 mm Hg. Follow-up venography after 74 ± 35 days in 6 patients, revealed ho restenosis, with further enlargement of the mean diameter by 5.2 ± 3.1 mm (44 ± 35%) and abolition of pressure gradients. One patient died 6 months after the procedure from acute Budd-Chiari syndrome. Autopsy revealed a widely patent stent with hepatic vein thrombus. Stent implantation is useful in the management of inferior vena cava obstruction with prior restenosis, total occlusion, or suboptimal results of balloon angioplasty.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.