Abstract
Ten patients (median age 36 yr, 5 male) with idiopathic IVC obstruction underwent balloon angioplasty followed by placement of a self-expanding stent due to unfavourable lesion characteristics. Six had total occlusion, 5 had restenosis (including 2 with total occlusion), and 1 had a suboptimal result after initial dilatation. Median minimum IVC diameter increased from 0 to 14.5 mm, and the median gradient across the lesion decreased from 16.5 to 1 mmHg. Follow-up venography (median interval 69 d) in six patients revealed no restenosis with further enlargement at the lesion site (median 4.5 mm) and abolition of gradients. Follow-up ultrasound in nine patients revealed no restenosis in the IVC. One patient died 6 mo after the procedure with acute Budd-Chiari syndrome due to hepatic vein occlusion. Autopsy revealed a widely patent stent with hepatic vein thrombus. Stent implantation is useful in the management of IVC obstruction with prior restenosis, total occlusion, or suboptimal result of balloon angioplasty.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.