Abstract
Recent results from full-scale static racking tests and small-scale lateral shear tests on plywood, oriented strand board (OSB), gypsum wallboard (GWB), and FiberBond wallboard (FB) attached to light gauge steel studs are presented and discussed in this paper. The objectives of the tests were to investigate the performance of sheathed light gauge steel framed shear walls and determine whether simple static lateral shear values for the panel connection can provide a useful correlation with full-scale test values. The full-scale tests were conducted in accordance with the basic test criteria defined in ASTM E 72-80. A procedure similar to that described in ASTM D 1761-88 was used for the small-scale tests. Panels used in the tests included 11.9 mm APA rated four-ply plywood sheathing, 11.1 mm APA rated OSB sheathing, 12.7 mm gypsum wallboard (ASTM C 36), and 12.7 mm FiberBond wallboard. Results obtained from tests showed that failure of the walls resulted from rotation (tilting) of the fasteners about the p...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.