Abstract
In this study, the evaluation of static and seismic bearing capacity factors for a shallow strip footing was carried out by using the method of characteristics, which was extended to the seismic condition by means of the pseudo-static approach. The results, for both smooth and rough foundations, were checked against those obtained through finite element analyses.Under seismic conditions the three bearing capacity problems for Nc, Nq and Nγ were solved independently and the seismic bearing capacity factors were evaluated accounting separately for the effect of horizontal and vertical inertia forces arising in the soil, in the lateral surcharge and in the superstructure.Empirical formulae approximating the extensive numerical results are proposed to compute the static values of Nγ and the corrective coefficients that can be introduced in the well-known Terzaghi׳s formula of the bearing capacity to extend its applicability to seismic design of foundations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.