Abstract
The purpose of this study is to test the effectiveness of mixing FeSO 4 and Fe 2(SO 4) 3 solutions with municipal solid waste incineration (MSWI) ash at room temperature to prevent heavy metals in treated ash from being dissolved. After conducting toxicity characteristic leaching procedure (TCLP) tests nine times, the accumulation of extracted lead from treated scrubber ash was lower than regulated limits by the sixth test. X-ray diffraction (XRD) and scanning electron microscopy/energy dispersive spectrometer (SEM/EDS) studies of the ash revealed that the mixed solution reacted with the scrubber ash to form Ca 4Fe 9O 17, which coated the surface of ash particles.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.