Abstract

Corrosion measurements on stainless-steel bins used to store high-level waste (HLW) calcines at the Idaho Chemical Processing Plant indicate an internal corrosion rate of 0.13 mm over 500 yr. From a corrosion standpoint, the existing bins or canisters stored in air will last more than 500 yr. Synthetic commercial HLWs solidified by fluidized-bed calcination have been stabilized (nitrates and water removed) at 620 to 720°C to permit their storage in sealed canisters. Heat transfer properties in the canister storage of the basic HLW forms were calculated, based on specified canister configurations, cooling media, and maximum permissible product or canister wall temperature, for a 1500 MTU/yr commercial reprocessing plant. The number of canisters required annually varies from ∼150 to 800 canisters/yr.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.