Abstract
An SR control with ZCD delay compensation is proposed to reduce the high reverse inductor current and input current distortion caused by the zero current detection (ZCD) delay in critical mode totem-pole power factor correction (PFC). The basic idea of the proposed control is to calculate the SR turn-off instant considering the ZCD delay. Accurate operation model in VOT control is analyzed with ZCD delay compensation to realize the proposed control. A prototype of 2 kW GaN CRM totem-pole PFC converter is built to verify the proposed control. The total harmonic distortion (THD) with full load decreases to 3% by mitigating the current distortion caused by the ZCD delay, 1.6% lower than that before compensation. The high reverse inductor current near the zero-crossing of input voltage is avoided since the length of the zero-current platform is shortened by 87.5%. The prototype achieves 99% efficiency at full load (2 kW) and a power density of 120 W/inch <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> .
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.