Abstract
Low pressure and reduced pressure fan and reduced pressure hollow cone nozzles were compared to conventional fan and hollow cone nozzles to determine their potential for reducing spray drift. Other comparisons included two different spray pressures for a low pressure fan nozzle, low and reduced pressure fan nozzles versus air-aspirating foam nozzles, low pressure versus reduced pressure fan nozzles, and reduced pressure hollow cone nozzles versus reduced pressure fan nozzles. Spray recoveries within 36 m downwind of the spray release point were significantly greater for the low pressure and reduced pressure fan and reduced pressure hollow cone nozzles than for the conventional fan and hollow cone nozzles. An air-aspirating nozzle producing spray without foaming adjuvant resulted in significantly greater spray recovery than a low pressure fan nozzle. The recovery from a reduced pressure fan nozzle having a rated flow of 12.6 cm3/s was significantly greater than that from a low pressure fan nozzle.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.