The effects of air and liquid properties and atomizer dimensions on the spray characteristics of plain-jet airblast atomizers are examined. Mean drop size and drop-size distribution are measured using an improved form of light scattering technique. The test range includes wide variations in air velocity, air pressure, air/liquid ratio, and liquid viscosity. The experimental data generally confirm the results of previous studies on prefilming types of airblast atomizers. They show that increases in air velocity, air pressure, and air/liquid ratio all tend to produce a more uniform spray and a lower mean drop size. It is also observed that any change in air properties, liquid properties, and atomizer geometry that lowers the mean drop size also produces a more uniform distribution of drop sizes in the spray.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.