A simple, rapid, selective and sensitive method for the micro amount determination of phenylephrine hydrochloride either in pure form (raw material) or in pharmaceutical formulations is described. The method is based on the development of violet colour charge transfer complex with haematoxylin in alkaline medium with 10 min after heating at 65 °C. The wavelength and maximum absorption range was found in the range from 640 to 620 nm. Molar absorptivity and Sandell sensitivity were found to be 2.38 × 10 4 L mol − 1 cm − 1 and 8.6 ng cm − 2 respectively. A linear correlation was found between absorbance (at the λ max) and concentration. The resulting colour is stable for more than 10 h. Results of the analyses of pure drug and dosage forms by the proposed method are in good agreement with those of the official BP 1998 procedure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.