Abstract

An emission spectrographic method for the estimation of impurities of Al, As, Ba, Bi, Ca, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mn, Mo, Ni, Pb, Sb, Sn, Te, Ti, V, Zn and Zr in high purity selenium at concentrations less than 1 ppm has been developed. The impurities were separated from 1 g of selenium by volatilizing Se from its solution in nitric acid and sulphuric acid. The residue containing impurities was dissolved in small amounts of 6 M HCl and loaded along with the washing on 10 mg mixture containing graphite (90%) and sodium chloride carrier (10%), in the electrode crater. The spectra were excited in a d.c. arc carrying 13 A. The detection limits lie in the range 0.005–0.5 ppm for the different elements. The precision of the method ranges from 7–18% for these elements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.