Abstract

Single-photon emission computed tomography (SPECT) ventilation perfusion (V/Q) scanning with low-dose computed tomography (LDCT) is an emerging imaging technique for investigation of suspected pulmonary embolism (PE). We aimed to estimate diagnostic utility of the combined technique using results from all patients referred in 2009 compared with final diagnosis and 6-month follow-up status. PE was diagnosed in 28 of 106 patients (26%), including in 2 of 80 (2%) with negative SPECT V/Q and LDCT. The estimated negative predictive value of SPECT V/Q for PE was 97%. LDCT was abnormal in 43 (41%) patients, including 41 patients who had negative SPECT V/Q. In 29 (27%) patients, LDCT provided information on alternative pathologies that accounted for presenting symptoms, and the combined technique had a diagnostic yield of 52%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.