Abstract

In this paper the low frequency harmonic distortion of the mains current of a three-phase single-switch discontinuous-mode boost-rectifier is calculated. The system analysis is based on application of space vector calculus and on substitution of discontinuous time shapes within a pulse period by quasicontinuous time shapes. The quasicontinuous time shapes are defined by averaging over the pulse period. The dependency of the shape of the input currents on the voltage transformation ratio is given for various control methods in analytical form. The results of the theoretical analysis are verified by digital simulation and by measurements on a laboratory model. A good consistency of the results has been found.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.