Abstract

This paper investigates the performance of a two level and a three level inverter drives for a permanent magnet synchronous machine (PMSM) under different switching frequencies. The experiments were conducted via a real time based system called Opal-RT. The inverters were operated at 1 kHz and 5 kHz switching frequencies. The torque was varied between 2 N.m and 4 N.m at a constant speed of 800 rpm. However the torque ripples and the copper losses between the two inverter drives were similar and the copper losses were independant of the swicthing frequency. At 5 kHz inverter switching frequency the two level inverter performed better at 4 N.m with a total current harmonic distortion of 2.55% and a torque ripple of 10%. However overall the three level inverter had low voltage and current harmonic distortion which translates to lower iron losses. Swicthing at 5 kHz frequency showed to have lower overall harmonic distortion than at 1 kHz for both inverters. The greater the capcitor voltage error the more the torque ripples even though the machine registered lower current total harmonic distortion for the three level inverter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.