Abstract
In the J-PARC user operation from Nov. 2020 – Apr. 2021, continuous operation of J-PARC Radio Frequency (RF) negative hydrogen ion (H-) source up to 3,651 hours (5 months) has been achieved. The ion source was operated with the output H- current of 60 mA, the duty factor (for plasma generation) 2% and the input RF power up to 30 kW. After the operation, phase space diagrams at the Radio Frequency Quadrupole linac (RFQ) entrance were measured by the emittance monitor at the ion source test stand (IS-TS) under the same operation condition as in the J-PARC Linac. Comparison of the phase spaces and the beam emittances between the ion sources in the present and the previous operations shows slight difference. From the direct observation of the antenna coil, no exhaustion or the decrease in the thickness of the enamel coating of the coil have been confirmed. The results indicate the possibility of the next goal of the long-run up to 7 months, which is the same as the full duration of the J-PARC user operation in 1 year.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.