Abstract

IntroductionMeniscal extrusion (ME) is an important indicator of and prognostic factor for various knee pathologies. To date, no standardized protocol for the ultrasound-based examination of lateral ME exists. The purpose of the present study was to test the reliability and validity of lateral ME measurements using a standardized ultrasound-based examination protocol.Materials and MethodsA group consisting of 11 healthy volunteers (Group I, male and female, 18–45 years) as well as a group of 10 consecutive patients who had undergone all-inside lateral meniscal radial tear repair were included (Group II, male and female, 23–43 years). Lateral ME, the main outcome parameter, was measured by ultrasound (US; both groups) and magnetic resonance imaging (MRI; Group II only). Both knees of all subjects were examined in an unloaded state and under axial compression of the knee (50% of body weight). Repeated measurements obtained in Group I by 2 observers were used for reliability testing, and the validity of US was assessed through comparison with MRI data (Group II).ResultsA total of 66 US images of Group I, obtained by each observer, were analyzed for reliability testing. Forty US and MR images of Group II were assessed for validation. Results showed good interrater (ICC = 0.904) and excellent intrarater (ICC = 0.942) reliability of US-based measurements of lateral ME. Agreement with MRI results was poor (ICC = 0.439), with US systematically overestimating results by 1.1 mm on average.ConclusionsUltrasound is a reliable, quick and cost-effective technique for lateral ME measurement, but results are not readily comparable with MRI.Trial registrationThe study was registered in the European Union Clinical Trials Register (EudraCT-Number: 2017-005037-24).

Highlights

  • Meniscal extrusion (ME) is an important indicator of and prognostic factor for various knee pathologies

  • Ten consecutive patients presenting for a follow-up (FU) examination after anterior cruciate ligament reconstruction and all-inside lateral meniscal radial tear repair were asked for participation for validity testing (Group II)

  • The intraclass correlation coefficient testified to good agreement of ratings (ICC = 0.904, 95% CI: 0.824–0.947)

Read more

Summary

Introduction

Meniscal extrusion (ME) is an important indicator of and prognostic factor for various knee pathologies. The purpose of the present study was to test the reliability and validity of lateral ME measurements using a standardized ultrasound-based examination protocol. Lateral ME, the main outcome parameter, was measured by ultrasound (US; both groups) and magnetic resonance imaging (MRI; Group II only). Both knees of all subjects were examined in an unloaded state and under axial compression of the knee (50% of body weight). Repeated measurements obtained in Group I by 2 observers were used for reliability testing, and the validity of US was assessed through comparison with MRI data (Group II). Conclusions Ultrasound is a reliable, quick and cost-effective technique for lateral ME measurement, but results are not readily comparable with MRI. The limits of physiological ME are patient-specific and best determined through comparison with the (healthy) contralateral side, serving as a reference value

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.