Abstract
In total knee arthroplasty (TKA), suboptimal restoration of joint line obliquity (JLO) and joint line height (JLH) may lead to diminished implant longevity, increased risk of complications, and reduced patient reported outcomes. The primary objective of this study is to determine whether restricted kinematic alignment (rKA) leads to improved restoration of JLO and JLH compared to mechanical alignment (MA) in TKA. This retrospective study assessed patients who underwent single implant design TKA for primary osteoarthritis, either MA with manual instrumentation or rKA assisted with imageless navigation robotic arm TKA. Pre- and post-operative long standing AP X-ray imaging were used to measure JLO formed between the proximal tibial joint line and the floor. JLH was measured as the distance from the femoral articular surface to the adductor tubercle. Overall, 200 patients (100 patients in each group) were included. Demographics between the two groups including age, sex, ASA, laterality, and BMI did not significantly differ. Distribution of KL osteoarthritis classification was similar between the groups. For the MA group, pre- to post-operative JLO significantly changed (2.94° vs. 2.31°, p = 0.004). No significant changes were found between pre- and post-operative JLH (40.6mm vs. 40.6mm, p = 0.89). For the rKA group, no significant changes were found between pre- and post-operative JLO (2.43° vs. 2.30°, p = 0.57). Additionally, no significant changes were found between pre- and post-operative JLH (41.2mm vs. 42.4mm, p = 0.17). Pre- to post-operative JLO alteration was five times higher in the MA group compared to the rKA group, although this comparison between groups did not reach statistical significance (p = 0.09). rKA-TKA results in high restoration accuracy of JLO and JLH, and demonstrates less pre- and post-operative JLO alteration compared to MA-TKA. With risen interest in joint line restoration accuracy with kinematic alignment, these findings suggest potential advantages compared to MA. Future investigation is needed to correlate between joint line restoration accuracy achieved by rKA and enhanced implant longevity, reduced risk of post-operative complications, and heightened patient satisfaction.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.