Abstract
A case study in NW Italy investigating an underground electric line (1 m depth triple cable at operative voltages 220-380 kV) measured electric fields in the surrounding soil virtually close to zero but magnetic fields (microTs) 20 times the background level. After 6 months, the influence radius around the cable on microbial activity (estimated by soil ATP), organic carbon, and total nitrogen follows exactly the inverse trend of the MF, shifting the biological activity with a lag distance of 5 m from the 220 kV cable.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.