Abstract

The use of solid supported membranes (SSM) was investigated for reconstitution of ion channels and for potential application to screen pharmacological reagents affecting ion channel function. The voltage-gated Kv1.5 K + channel was reconstituted on an SSM and a current was measured. This current was dependent on the presence of K +, but not Na +, indicating that the Kv1.5 K + channel maintained cation specificity when reconstituted on SSM. Two pharmacological reagents applied to Kv1.5 K + channels reconstituted on SSM had similar inhibitory effects as those measured using Kv1.5 in biological membranes. SSM-mounted ion channels were stable enough to be washed with buffer solution and reused many times, allowing solution exchange essential for pharmacological drug screening.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.