Abstract

Soil water content and dry density are two important properties for compaction quality control. This paper presents a new method for determining soil water content and dry density using a single time domain reflectometry test, which is an improvement over that designated by ASTM D6780. This new method is based on simultaneous measurement of apparent dielectric constant and bulk electrical conductivity on the same soil sample. Calibration equations correlate these two parameters with soil gravimetric water content and dry density, which are simultaneously solved after adjusting field-measured conductivity to a standard conductivity. The method compensates for temperature effects. The test process takes about 3 min and all calculations are automated. Testing may be done in situ using a special probe that provides sufficient sampling volume or in a compaction mold adapted to form a probe. Laboratory and field tests results show this one-step method is a fast, accurate, and safe method for construction quality control.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.