Abstract

Measurements to date of the wavelength dependency of gain recovery time in semiconductor optical amplifiers (SOAs) have mostly used pump-probe techniques with a pump and probe operated on distinct wavelengths. Choice of pump wavelength, and its relative proximity to the probe wavelength, could influence measurements and impede unambiguous observation of wavelength dependence on recovery dynamics. We use a single-color pump-probe measurement technique to directly access the wavelength dependence of the gain recovery time in bulk InGaAsP SOAs. We used ultrashort pulses from a single mode locked laser to measure unambiguously the spectral dependency and temporal behavior of SOAs. Simulation results using a model that takes into account intra-band and inter-band contributions to SOA saturation, as well as experimental results for the SOA tested, show recovery rate dependency similar to gain spectrum.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.