Abstract

This paper focuses on methodologies for calculation and examination of oscillatory security of interconnected power system network against constant disturbances. For instance, voltage soundness, transient dependability and oscillatory behaviors are also the measure of power system stability, which must be evaluated. For that proposed strategies based on proportional integral and fuzzy logic controlling techniques are implemented. The integral controller-based technique provides the zero steady-state error and with adequate damping, time to reach steady state can be reduced, on the cost of oscillation in frequency and tie-line power. On the contrary, fuzzy logic has demonstrated that strategies of computational intelligence can alleviate the quick appraisal of oscillatory solidness with less time to reach steady state. Furthermore, Eigenvalues are constructed for small signal stability analysis, utilizing a parallel variation of Arnoldi technique, reducing the time essential for calculation of vast Multi-Area power frameworks. For exhibit purposes, models have been composed utilizing MATLAB/SIMULINK and with the assistance of the fuzzy logic.

Highlights

  • Control frameworks of the multiarea system are consistently developing with even bigger limits of power and voltage[1]

  • As it is shown in the figure below that no error signal is generated in the power system if no controller is employed, and with Proportional Integral (PI) controller, a steady error signal is generated [29]

  • PI controllers would be employed so as to make system response stable and sustainable during dynamic conditions. In this simulation result we are able to see that when it comes to power pools which are connected together, due to constant and abrupt fluctuations in the power output, in this case taking into consideration the rapid and spontaneous small variations in the load of the three-area control system, there will be a corresponding deviation from their standard values for both frequency as well as tie-line power passing through these interconnectors [23]

Read more

Summary

Introduction

Control frameworks of the multiarea system are consistently developing with even bigger limits of power and voltage[1]. Present day control frameworks are of a huge size, extending over a wide area of interconnected systems with various divisions and generating stations. Multi-Area power system architecture is more favourable for the deregulated power industry and distributed generation. With the enormous growth of power system, congestion of the power transportation corridors remains as a challenge, the transmission system operator (TSO) might be forced to put up serious measures so as to reduce the thermal limit capacities as a result of this overloading of the power transmission corridors. A three-area power system is simulated with Proportional Integral (PI) and Fuzzy Logic (FL) control scheme to enhance the reliability and stability of power system. The proposed model consists of two thermal generators and one gas turbine system for power generation which is having a much faster response. Transients due to constant load change, about 2 to 5% of total load in step form, are imposed [12]

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.