Abstract
In the manufacturing process of the 10 kV induction motors, a semi-conductive layer with certain resistance covering the linear part of the stator coil is often used to suppress the partial discharges (PDs) happened in the slot. However, due to electromagnetic force while the motor is running, slot discharge is still one of the main causes of stator insulation degradation. In this paper, an adjustable width mockup core slot is designed using silicon steel sheet. Several 10 kV real machine stator coils subjected to varying aging degrees are adopted as test coils. The phase resolved partial discharge (PRPD) patterns of slot discharge are analyzed using a PRPD analyzer and the variation law of slot discharge patterns with voltage variation is illustrated. The investigation result has been applied to the online monitoring and pattern recognition of the insulation for a 10 kV induction motor in a coal mine and it has great application significance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Dielectrics and Electrical Insulation
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.