Abstract
In this paper, an attempt has been made to study the slot discharge pattern occurring in the stator coils at various frequencies and maintained at different surface temperature. Epoxy-mica based stator coils were used in the present study. Slot discharges were simulated in stator coils by partially removing semi conducting tape from the insulation surface and clamping a steel flat over the exposed insulation, which acts as stator core. Partial discharge measurements were carried out on 6.6 kV stator coils with simulated slot discharges. The Phase Resolved Partial Discharge pattern of slot discharge and the variation in the slot discharge characteristics due to increase in surface temperature of the stator coil is compared at different frequencies. The partial discharge characteristics and Phase Resolved Partial Discharge pattern were found dependent on excitation voltage frequency. The results are summarized and discussed in this paper.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.