Abstract

This paper presents the results of the proton irradiation of silicon photomulipliers (SiPMs) by mono-energetic 170 MeV protons with fluence up to 4.6×109 particles/cm2. In our work, three types of silicon photodetectors from Hamamatsu with areas 3×3 mm2 and different subpixel sizes of 25×25 μm2, 50×50 μm2, and 75×75 μm2 were used. The changes in the SiPM dark count rate (DCR) spectrum before and after irradiation in temperatures in the range of 20̂C to −65̂C are presented. The influence of the DCR changes on the energy resolution of the 662 keV gamma line from the 137Cs for a non-irradiated GAGG:Ce (1%) scintillator is investigated. The time period of usability of the SiPM detector irradiated by protons in cosmic space was estimated.