Abstract

Multipass dynamic MRI and pharmacokinetic modeling are used to estimate perfusion parameters of leaky capillaries. Curve fitting and nonblind deconvolution are the established methods to derive the perfusion estimates from the observed arterial input function (AIF) and tissue tracer concentration function. These nonblind methods are sensitive to errors in the AIF, measured in some nearby artery or estimated by multichannel blind deconvolution. Here, a single-channel blind deconvolution algorithm is presented, which only uses a single tissue tracer concentration function to estimate the corresponding AIF and tissue impulse response function. That way, many errors affecting these functions are reduced. The validity of the algorithm is supported by simulations and tests on real data from mouse. The corresponding nonblind and multichannel methods are also presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.