Abstract

A rapid and simple ultra high performance liquid chromatography with tandem mass spectrometry method was developed and validated for the simultaneous separation and determination of vancomycin and its crystalline degradation products in human serum. Vancomycin and two isomers of the degradants were extracted from human serum with a protein precipitation method. The compounds were separated on an Acquity BEH C18 column (2.1 × 50mm, 1.7 μm) eluted with a gradient mixture of acetonitrile and 0.1% formic acid as the mobile phase. Norvancomycin was used as the internal standard. The linear ranges of vancomycin and two degradant isomers were 1.057-105.7, 0.1437-14.37, and 0.2540-25.40μg/mL, respectively. The established methods were validated and successfully applied to a therapeutic drug monitoring study of vancomycin in patients with renal insufficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.