Abstract

An ultra-performance liquid chromatography-triple quadrupole/linear ion trap mass spectrometry (UPLC-Qtrap MS) method was developed for the determination of 84 toxic plant constiuents in plasma and urine. Plasma was precipitated by acetonitrile to remove proteins and then passed through a Prime HLB SPE column to remove phospholipids, while urine was diluted with methanol. Chromatographic separation of the analytes was achieved on an Acquity BEH C18 column (100 mm×2.1 mm, 1.7 μm) by gradient elution using the mobile phase of 0.1% (v/v) formic acid and 2 mmol/L ammonium formate both in 97% (v/v) acetonitrile aqueous solution and water. Electrospray ionization mass spectrometry was carried out in the positive ion mode with multiple reaction monitoring-information dependent acquisition-enhanced product ion scan mode (MRM-IDA-EPI). The 84 analytes were quantified by the matrix working standard curve internal standard method, and a good linear relationship was observed, with correlation coefficients of ≥ 0.9911. The limits of detection (LODs) in plasma and urine were 0.01-1 μg/L and 0.03-2 μg/L, respectively. The intra- and inter-day precisions of these analytes were 0.7%-18.4% and 1.1%-18.5%, and the accuracy of all analytes ranged from 70.6% to 124.5%. This method is simple, sensitive, and accurate for the measurement of these analytes in plasma and urine for both clinical and forensic applications.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call