Abstract
Background: Pantoprazole (PTZ) and Levosulpiride (LS) were proven as effective agents for the treatment of Gastro-Esophageal Reflux Disease (GERD). It is a complex motor disorder that results in regurgitation of the gastric contents into the lower esophagus with consequent symptoms such as heart burn, retrosternal pain, dysphagia and belching. Methods: A rapid, sensitive, selective and specific liquid chromatography- electro spray ionization tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous quantification of Pantoprazole (PTZ) and Levosulpiride (LS) in spiked Human Plasma. The method utilized SPE as sample preparation technique and the analysis was carried out on a HPLC system utilizing electro spray ionization as interface and triple quadrupole mass analyzer for quantification in MRM possitive mode. Iloperidone was used as internal standard (IS). Chromatographic separation was performed on a Phenomenex C-18 Column (4.6 mm x 50 mm, 5µ) with an isocratic elution mode utilizing a mobile phase composition of Solution containing a mixture of 70 volumes of acetonitrile: 30 volumes of methanol and 10mM ammonium formate (pH 4.0) at the ratio of 80:20 % v/v. The flow rate was maintained at 0.3 mL/min. Results: PTZ, LS and IS were detected and quantified with proton adducts at m/z 383.37→200.00, m/z 341.42→112.15 and 426.48→261.00 respectively. The linearity and range was established by fortifying blank plasma samples in the concentration range of 3.5-2000 ng/mL for PTZ and 3.0-2400 ng/mL for LS. The correlation coefficient (r2) was found to be ≥ 0.993 for PTZ and (r2) ≥ 0.990 for LS. The lower limit of quantification for PTZ was 3.5 ng/mL and LS was 3.0 ng/mL. The intra and inter day precision and accuracy for PTZ and LS were within the limits fulfilling the international acceptance criteria. PTZ and LS were found to be stable throughout three freeze-thaw cycles, bench top and short term stability studies. Conclusion: The proposed validated LC-MS/MS method offers a sensitive quantification of PTZ and LS in spiked human plasma and can be utilized for the quantification of PTZ and LS in real-time samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.