Abstract
A novel, highly sensitive dual-parameter sensor based on tandem-interferometric arrangement of Fabry–Perot interferometer and Mach–Zehnder interferometer (MZI) has been designed and implemented in this paper. The sensor is composed of a single-mode fiber (SMF), hollow-core fiber, no-core fiber (NCF), and photonic crystal fiber (PCF). Those can simultaneously form a Fabry–Perot interferometer and a MZI. The both interferometers are able to measure strain. Meanwhile, the PCF was filled with liquid crystal to measure electric field intensity. Hence, simultaneous measurement of electric field and strain can be achieved. The sensitivities of electric field and strain can reach up to 10.5 nm/(kV/mm) and 1.25 pm/ $\mu \varepsilon $ , respectively.