Abstract

A simple, step by step, cost-effective, accurate, sensitive, and selective validated High Performance Thin Layer Chromatographic method for simultaneous determination of Terbutaline sulphate, Ambroxol hydrochloride, and Guaifenesin in syrup formulation has been developed and validated. HPTLC separation was achieved on Merck aluminum HPTLC plates precoated with silica gel 60 F254. The solvent system comprised of Chloroform: Methanol: Ethyl acetate: Acetic acid: Formic acid (7.0:1.4: 0.8:1.0:0.5 v/v). Densitometric detection wavelength at 200 nm was used in reflectance-absorbance mode. The retention factors were found to be 0.32±0.02, 0.55± 0.02, and 0.72±0.02, for Terbutaline sulphate, Ambroxol hydrochloride, and Guaifenesin respectively. Results were found to be linear over a range of 200 - 700ng band-1, 1000 - 7000ng band-1, and 400-1200ng band-1 for Terbutaline sulphate, Ambroxol hydrochloride, and Guaifenesin, respectively. The percent assay was found to be 98.47%, 98.47%, and 99.23%, for Terbutaline sulphate, Ambroxol hydrochloride, and Guaifenesin, respectively in marketed formulation. The developed densitometric method was validated by following the International Council on Harmonisation (ICH) guideline. The developed and validated chromatographic method can be applied for routine quality control of Terbutaline sulphate, Ambroxol hydrochloride, and Guaifenesin in the combined syrup dosage form used in study.