Abstract

A sensitive and selective high-performance liquid chromatographic method has been developed for a new sulphonylurea, glimepiride, and its metabolites. The assay involves extraction with diethyl ether, thermolysis of the sulphonylureas at 100°C and trapping of the resulting amines with 2,4-dinitrofluorobenzene. The derivatives were quantitated on a reversed-phase column by absorbance at 350 nm using a step gradient for the three compounds in serum and an isocratic run for the metabolites in urine. Analogous compounds were used as internal standards. The detection limit was 5 ng/ml for glimepiride and metabolite II and 10 ng/ml for metabolite I using 1 ml of serum. The method has been applied to the analysis of serum and urine samples from pharmacokinetic studies in humans.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.